Testing your Orbit sprinkler system before the growing season starts can save you from a dry, brown lawn and costly water bills. A full test checks each zone for leaks, broken heads, and proper coverage, and it also confirms that your controller and valves are communicating correctly. You don’t need special tools—just a few minutes and a willingness to get your hands a little wet. This guide walks you through the entire process, from checking the controller to adjusting each sprinkler head.
What You’ll Need
- Flathead screwdriver (for adjusting spray heads)
- Adjustable wrench or pliers (for tightening connections)
- Small shovel or trowel (to dig around buried heads if needed)
- Gloves (optional, but handy for dirty work)
- Bucket or container (to catch water when checking flow)
- Paper and pen (to note any issues per zone)
Step-by-Step
- Turn off the water supply. Locate the main shutoff valve for your irrigation system—usually a brass or plastic valve near your water meter or where the system connects to the house. Turn it clockwise to close it completely.
- Inspect the controller. Open your Orbit controller (the timer box, usually mounted in the garage or on an exterior wall). Check the display for any error codes, and make sure the batteries are fresh if it’s a battery-powered model. Note the current date and time settings—they should be correct for the season.
- Set the controller to manual test mode. Most Orbit controllers have a dial or button labeled “Manual” or “Test.” Turn the dial to this position. If you’re unsure, consult your specific model’s manual—the goal is to run each zone manually, one at a time, without waiting for the scheduled program.
- Turn the water supply back on. Slowly open the main shutoff valve. Do this gradually to avoid a sudden surge of water that could damage pipes or heads. Listen for any hissing sounds that might indicate a leak.
- Run the first zone. On the controller, select zone 1 and press the “Start” or “Manual” button. The valve for that zone should open, and water should begin flowing to the sprinkler heads. Walk out to the yard and observe each head in that zone.
- Check each sprinkler head. For every head in the zone, look for:
- Proper pop-up: The head should rise fully out of the ground. If it doesn’t, there may be debris blocking it or a broken spring.
- Even spray pattern: Water should spray in a consistent arc and reach the intended area without hitting the house, sidewalk, or driveway excessively.
- No leaks: Look for water pooling around the base of the head, which indicates a loose connection or a cracked riser.
- No drips: After the zone stops, the head should not continue to drip for more than a few seconds—that suggests a faulty valve or a worn seal.
- Check water pressure. If the spray is weak or misting, the pressure may be too low or too high. A normal spray should be a steady stream, not a fine fog. If you see misting, the pressure is too high—you may need a pressure regulator. If the spray is barely reaching, there may be a clog or a leak somewhere in the line.
- Adjust heads as needed. Use a flathead screwdriver to turn the adjustment screw on top of each spray head. Turn clockwise to reduce the spray radius, counterclockwise to increase it. For rotor heads, use the tool provided or a flathead to adjust the arc and distance. Make small adjustments and re-test.
- Move to the next zone. Once you’ve inspected and adjusted all heads in zone 1, stop that zone from the controller (press “Stop” or turn the dial to “Off”), then select zone 2 and repeat steps 5–8. Continue for all zones in your system.
- Check the controller’s program. After testing all zones manually, return the dial to the “Auto” or “Run” position. Review your programmed start times and durations for each zone. Adjust them based on what you observed—for example, if a zone has poor coverage, you may need to increase its run time.
- Do a final full-system check. Turn the controller to “Auto” and let it run through one complete cycle. Walk the yard during this cycle to confirm everything works as expected. Note any issues that require parts or professional help.
Common Mistakes
- Forgetting to turn the water back on. It sounds obvious, but it’s easy to leave the main valve closed after winterizing. If nothing happens when you test, check the valve first.
- Testing with the controller in the wrong mode. If you leave the dial on “Off” or “Rain Delay,” the system won’t run. Make sure you’re in a manual test mode.
- Ignoring low heads. A head that’s sunk below ground level will waste water and create a puddle. Dig around it and raise it to the proper height (flush with the soil).
- Over-adjusting spray heads. Turning the screw too far can break the head or cause it to stop rotating. Make small adjustments (quarter turns) and test after each.
- Skipping the backflow preventer. If your system has a backflow preventer, it should be checked for leaks or stuck valves. A faulty backflow can cause contamination and reduce water flow.
Tips
- Test early in the morning. Water pressure is usually highest in the early morning, and you’ll have daylight to see the spray patterns clearly.
- Keep a notepad. Write down which zones have issues, what the problem is, and what you did to fix it. This helps you track recurring problems.
- Check the filter screens. Many Orbit heads have a small filter screen inside the stem. If a head is weak, remove the head, clean the screen, and reinstall.
- Inspect the valve boxes. While testing each zone, open the valve box for that zone and look for leaks or debris around the solenoid and diaphragm.
- Consider a professional audit. If you have a large system or persistent issues, a professional irrigation audit can measure coverage and efficiency, but that’s optional for most homeowners.
Troubleshooting
- Zone doesn’t start at all. Check that the controller is in the correct mode and that the zone is selected. If it still won’t start, the valve may be stuck or the solenoid may be faulty. Try turning the solenoid screw (on top of the valve) counterclockwise to manually open the valve—if water flows, the problem is electrical. Check wiring connections at the controller and valve.
- Water sprays but head doesn’t pop up. This usually means debris is blocking the head or the riser is broken. Dig around the head, clean out any dirt, and check the riser for cracks. If the spring is broken, replace the head.
- Uneven spray or puddles. This could be a clogged nozzle or a tilted head. Clean the nozzle with a pin, and adjust the head so it’s level with the ground.
- Low water pressure across all zones. Check the main shutoff valve—it may be partially closed. Also check for a kinked supply line or a clogged filter at the backflow preventer.
- Water continues to run after the zone stops. This indicates a valve that isn’t closing fully. Turn off the water, disassemble the valve, and clean the diaphragm. If it’s worn, replace it.
- Controller shows an error code. Look up the code in your manual. Common issues include a short circuit in the wiring or a faulty valve solenoid. Test each zone individually to isolate the problem.
Frequently Asked Questions
How often should I test my Orbit sprinkler system?
You should do a full manual test at least once a year, ideally in early spring before the first heavy watering. Also do a quick visual check monthly during the watering season.
Can I test a zone without turning on the controller?
Yes. You can manually open the valve by turning the solenoid screw (usually a small knob) counterclockwise. This is useful for testing a single zone without running the full program.
Why is one sprinkler head not spraying even though the zone is on?
Most likely a clogged nozzle, a broken riser, or a stuck pop-up mechanism. Remove the head, clean it, and check for damage. If the head is old, replacement is often the easiest fix.
What should I do if water is leaking from the base of a sprinkler head?
Turn off the water, unscrew the head, and check the rubber gasket or O-ring. Replace if worn. Also tighten the connection to the riser, but don’t overtighten.
Is it normal for some heads to spray less than others in the same zone?
Yes, if the system has elevation changes or long pipe runs. However, if the difference is significant, check for clogs or a partially closed valve. You may also need to install a pressure regulator on that zone.
How long should each zone run?
It depends on soil type, sun exposure, and plant type. A typical start is 10–15 minutes per zone, 3 times a week. Adjust based on how quickly water pools or runs off.
Related
General steps for current mainstream versions; menus can differ by device and version. See the disclaimer or report an error.
More in this bed
- K Factor 8 Sprinkler: Meaning and Flow Rates
- Free Online Sprinkler System Layout Design
- Sprinkler Pump 1 hp: Is It Enough?
- Typical Sprinkler Head Flow Rate: GPM Guide
- Rain Bird Sprinkler Manual: Setup, Settings & Fixes
- K Factor of Sprinkler: Definition & How to Use It