The Hunter 2 sprinkler valve is a 2-inch, electrically activated (24 VAC) globe valve used in commercial and large residential irrigation systems to control water flow to a zone or mainline. It is not a specific model name but a size class within Hunter’s valve lineup, most commonly the ICV-200 or PGV-201, and it is chosen when a system needs high flow rates (typically 40–200+ GPM) that 1-inch or 1.5-inch valves cannot handle.
Background: Where the Hunter 2 Fits in Irrigation
Hunter Industries makes a range of irrigation valves, from small 3/4-inch residential models to large 3-inch commercial units. The “2” refers to the nominal pipe size (2 inches), meaning the valve’s inlet and outlet are designed to connect to 2-inch PVC or similar pipe. These valves are almost always installed underground in a valve box and are controlled by an irrigation controller (timer) that sends a 24-volt AC signal to a solenoid on the valve. The Hunter 2 is used for mainline zoning, large turf areas (golf courses, parks, sports fields), or as a master valve that shuts off the entire system when not in use.
Common models in this size include the ICV-200 (a heavy-duty commercial valve with a flow-control stem and a manual bleed screw) and the PGV-201 (a mid-range valve designed for both residential and light commercial use). Both are globe-style valves, meaning the water flows through a 90-degree turn inside the body, which allows for smooth throttling and reliable shutoff.
How the Hunter 2 Sprinkler Valve Works
Like most irrigation valves, the Hunter 2 is a diaphragm valve. The key parts are:
- Body – the main housing, usually made of reinforced plastic or brass (for high-pressure applications).
- Diaphragm – a flexible rubber membrane that opens or closes the water passage.
- Solenoid – an electromagnetic coil that, when energized with 24 VAC, lifts a small plunger to release pressure from the top of the diaphragm.
- Flow control stem – a manual screw that adjusts the maximum opening of the valve, limiting flow even when fully open.
- Bleed screw – a small screw that allows manual opening of the valve without electricity (by releasing pressure from the diaphragm chamber).
When the controller sends power to the solenoid, the plunger lifts, allowing water from the top chamber to escape to the downstream side. The pressure above the diaphragm drops, and the higher inlet pressure pushes the diaphragm up, opening the valve. When power is removed, the plunger closes, pressure builds above the diaphragm again, and the valve closes. The 2-inch size means the diaphragm is large, allowing a high flow rate with relatively low pressure loss.
Choosing Between the Hunter 2 and Smaller Valves
Selecting the right valve size is critical for system performance. A valve that is too small causes excessive pressure drop and poor sprinkler performance; one that is too large may not open fully or may cause water hammer. Here are factors to consider:
- Flow rate (GPM) – Calculate the total flow of all sprinklers in the zone. A 2-inch valve is typically rated for 40–200 GPM. If your zone needs more than 150 GPM, a 2-inch is often necessary; if under 30 GPM, a 1-inch valve is better.
- Pipe size – The valve should match the pipe diameter on both sides. If your mainline is 2-inch, a 2-inch valve avoids reducers and keeps flow smooth.
- Pressure loss – Check the valve’s pressure loss chart. At 100 GPM, a 2-inch valve might lose only 2–3 PSI, while a 1-inch valve could lose 8–10 PSI.
- Controller compatibility – All Hunter 2 valves use standard 24 VAC solenoids, so they work with any irrigation controller that provides 24 VAC (most do).
- Manual operation – If you need to open the valve manually without a controller, look for a model with a bleed screw or a manual flow control knob.
Common Problems and Troubleshooting
Even reliable valves fail. Here are the most frequent issues with Hunter 2 valves and how to address them:
- Valve won’t open – Check the controller wiring and solenoid. Use a multimeter to test for 24 VAC at the solenoid wires. If power is present but the valve doesn’t open, the solenoid may be stuck; remove and clean it, or replace it.
- Valve won’t close – Debris (sand, gravel) can lodge under the diaphragm. Turn off the water, disassemble the valve, and clean the diaphragm and seat. Also check that the flow control stem is not turned down too far.
- Leaking around the bonnet – The bonnet (top cover) may be loose or the O-ring damaged. Tighten the screws evenly or replace the O-ring.
- Water hammer – If the valve closes too quickly, it can cause a loud bang. Install a flow control or a pressure-regulating module to slow the closure, or open the flow control partially.
- Low flow at sprinklers – The valve might be partially closed (flow control too tight) or there is a blockage in the screen filter inside the valve. Clean the filter.
Hunter 2 vs. Other Valve Types and Brands
Within the 2-inch class, you might compare the Hunter ICV-200 to the Rain Bird 200-DV or the Toro 252. All are similar in function, but differences exist in materials, warranty, and pressure ratings. The Hunter ICV is known for its durable construction and a captive diaphragm that simplifies maintenance. The PGV series is slightly lighter and less expensive, but still reliable. For high-pressure systems (over 150 PSI), you may need a brass-bodied valve, but most residential/commercial systems are under 100 PSI, so plastic is fine.
Also, note that a 2-inch valve is not the same as a 2-inch sprinkler head. Sprinkler heads are measured by their nozzle size or radius, not pipe size. The valve is just the on/off switch for the water.
Installation and Maintenance Tips
Installing a Hunter 2 valve is a straightforward plumbing job, but follow these guidelines:
- Turn off the water supply and drain the line.
- Glue the valve into the PVC pipe using primer and solvent cement, ensuring the flow arrow points in the direction of water flow.
- Place the valve in a valve box with gravel at the bottom for drainage, and leave room for the solenoid and bleed screw to be accessible.
- Wire the solenoid to the controller using waterproof connectors (e.g., grease caps). Use 18-gauge or heavier wire for runs over 200 feet to avoid voltage drop.
- After installation, open the main water supply slowly and bleed the air by opening the bleed screw slightly until water flows, then close it.
- Test the valve manually and with the controller. Adjust the flow control to match the zone’s needs (usually full open unless you need to limit flow).
Maintenance is minimal: every few years, disassemble the valve and clean the diaphragm and screen. In freezing climates, drain the valve or blow out the system with air before winter to prevent cracking.
Cost and Where to Buy
Prices for a Hunter 2-inch valve vary by retailer and model, but generally range from $60 to $120 for a plastic body. The ICV-200 is typically at the higher end, while the PGV-201 is more budget-friendly. You can find them at irrigation supply stores, online retailers, or big-box home improvement stores. Always buy from a reputable seller to avoid counterfeit products. Also, consider buying a rebuild kit (diaphragm and O-rings) for future maintenance, usually around $15–$25.
Frequently Asked Questions
Can I use a Hunter 2 valve for a residential lawn?
Yes, but only if your zone’s flow rate exceeds what a 1-inch valve can handle (usually over 30–40 GPM). Most residential zones use 1-inch or 3/4-inch valves because typical sprinkler zones flow 10–20 GPM. Using a 2-inch valve on a small zone can cause the valve to not open fully, leading to poor performance.
How many sprinkler heads can a Hunter 2 valve run?
It depends on the nozzle flow rates. For example, if each rotor uses 5 GPM, a 2-inch valve can handle up to 40 heads (200 GPM). But you must also consider pipe size and pressure. A general rule is to keep the total flow under the valve’s maximum rating and ensure the pipe can deliver that flow without excessive friction loss.
What is the difference between the ICV and PGV series?
The ICV (Inline Commercial Valve) is a heavier-duty valve with a thicker body, a captive diaphragm, and a flow control that can be locked. The PGV (Professional Grade Valve) is lighter, often less expensive, and has a simpler design. Both are reliable, but the ICV is better for high-usage commercial installations.
How do I manually open a Hunter 2 valve without power?
Look for the bleed screw on the top of the valve (usually a small brass or plastic screw). Turn it counterclockwise about a half-turn to release pressure from the diaphragm chamber, which will open the valve. Some models also have a manual flow control knob that can be turned to open. Remember to close the bleed screw after manual operation.
Can I use a 2-inch valve on a 1.5-inch pipe?
Yes, you can use reducers to connect a 2-inch valve to 1.5-inch pipe, but this may create turbulence and reduce flow efficiency. It’s better to match the valve to the pipe size. If your pipe is 1.5-inch, consider a 1.5-inch valve instead.
Why does my Hunter 2 valve vibrate or hum?
A humming sound often indicates the solenoid is not fully seated or the voltage is too low. Check the solenoid connection and ensure the controller is providing a solid 24 VAC. Also, check for debris in the valve that might cause the diaphragm to flutter. Cleaning the valve usually resolves the issue.
Related
General steps for current mainstream versions; menus can differ by device and version. See the disclaimer or report an error.
More in this bed
- K Factor 8 Sprinkler: Meaning and Flow Rates
- Free Online Sprinkler System Layout Design
- Sprinkler Pump 1 hp: Is It Enough?
- Typical Sprinkler Head Flow Rate: GPM Guide
- Rain Bird Sprinkler Manual: Setup, Settings & Fixes
- Hunter Sprinkler Valve Diagram Explained