Inverter Run Time Calculator: How Long Will It Last?

Tag 08-3738 · Updated · Standard formula, shown below

Run Time 3.60 h
Energy Available
1,080.0 Wh
Result
Battery Capacity
100 Ah
You entered
Battery Voltage
12 V
You entered
You enter
Battery Capacity, Battery Voltage, Inverter Efficiency, Load Power
You get
Run Time, Energy Available
Rounding
2 dp · 1 dp

An inverter run time calculator estimates how long a battery-powered inverter can keep a load running before the battery is drained. You enter the battery capacity (amp-hours), battery voltage, inverter efficiency, and the power draw of your devices (watts), and the calculator returns the expected run time in hours and minutes. This page explains the formula, shows a worked example, and covers the real-world factors that make the actual run time differ from the estimate.

Formula

The calculator uses the fundamental energy relationship: energy (watt-hours) equals power (watts) multiplied by time (hours). The energy available from the battery is the battery voltage times the amp-hour rating, adjusted for inverter efficiency. The formula is:

Run Time (hours) = (Battery Capacity (Ah) × Battery Voltage (V) × Inverter Efficiency (%)) / Load Power (W)

Where:

  • Battery Capacity (Ah) – the amp-hour rating of the battery (e.g., 100 Ah for a typical deep-cycle battery).
  • Battery Voltage (V) – nominal battery voltage (12V, 24V, 48V are common).
  • Inverter Efficiency (%) – the percentage of DC power converted to AC power (typically 85–95%).
  • Load Power (W) – the total wattage of the devices you plan to run (e.g., a 300W TV).

The result is in hours. To get minutes, multiply the decimal part by 60.

Worked Example

Using the default values from the calculator: a 100 Ah, 12V battery, 90% inverter efficiency, and a 300W load.

  1. Calculate usable energy: 100 Ah × 12V = 1200 Wh (battery energy).
  2. Apply inverter efficiency: 1200 Wh × 0.90 = 1080 Wh (usable AC energy).
  3. Divide by load: 1080 Wh ÷ 300W = 3.6 hours.

The calculator shows 3.60 hours, which is 3 hours and 36 minutes. That matches the step-by-step calculation.

Why the Estimate Is Often Optimistic

Real-world run time is usually shorter than the calculator suggests for several reasons:

  • Battery capacity is not fully usable. Deep-cycle lead-acid batteries should not be discharged below 50% to avoid damage. That cuts usable capacity in half. Lithium batteries (LiFePO4) can be discharged to 80–90%.
  • Inverter efficiency varies with load. Inverters are most efficient at 50–80% of their rated capacity. At very low loads, efficiency can drop below 80%.
  • Battery voltage drops under load. As the battery discharges, voltage sags, reducing the actual watt-hours delivered.
  • Temperature effects. Cold batteries deliver less capacity; heat increases self-discharge.
  • Startup surges. Motors and refrigerators draw several times their running wattage for a few seconds, which can trip the inverter or drain the battery faster.

For lead-acid batteries, a practical rule is to use 50% of the rated amp-hours in the calculation. For lithium, use 80–90%.

How to Choose the Right Inverter and Battery

To get the run time you need, you must match the inverter and battery to the load.

  1. List all devices you want to run and their wattages. Add them up to get the total load.
  2. Choose an inverter rated at least 20% higher than the total load to handle surges.
  3. Decide how many hours you need to run the load.
  4. Calculate the required battery capacity using the formula rearranged: Battery Ah = (Load W × Hours) / (Voltage × Efficiency).
  5. Apply the depth-of-discharge factor: divide by 0.5 for lead-acid, 0.8 for lithium.

For example, to run a 500W load for 5 hours on a 12V system with 90% efficient inverter and lithium battery (80% usable):

  • Energy needed = 500W × 5h = 2500 Wh.
  • Battery energy = 2500 Wh / 0.90 = 2778 Wh.
  • Battery Ah = 2778 Wh / 12V = 231 Ah.
  • With 80% discharge: 231 / 0.8 = 289 Ah.

So you would need a 300 Ah lithium battery (or two 150 Ah in parallel).

Common Mistakes and Misconceptions

  • Using amp-hours without voltage. A 100 Ah 12V battery stores 1200 Wh, but a 100 Ah 24V battery stores 2400 Wh. Always convert to watt-hours.
  • Ignoring inverter efficiency. Inverters waste 5–15% as heat. The calculator includes this, but many simple estimates do not.
  • Confusing watts and volt-amps. Some devices (like power supplies) are rated in VA. For resistive loads, VA = watts, but for reactive loads, watts can be lower. Check the device label.
  • Forgetting the inverter’s own draw. The inverter itself consumes power when on, even with no load (typically 5–20W). This can matter for long run times.
  • Assuming the battery can deliver its full rated capacity at high discharge rates. Lead-acid batteries deliver less capacity when discharged quickly (Peukert effect). A 100 Ah battery may only give 70 Ah at a 10-hour discharge rate.

Real-World Run Time Examples

Here are typical run times for common devices using a 12V, 100 Ah battery (1200 Wh) and a 90% efficient inverter (1080 Wh usable).

  • LED TV (100W): 1080 Wh / 100W = 10.8 hours.
  • Laptop (60W): 1080 / 60 = 18 hours.
  • Mini fridge (80W average): 1080 / 80 = 13.5 hours, but the compressor surge may be higher.
  • CPAP machine (30W): 1080 / 30 = 36 hours.
  • Electric heater (1500W): 1080 / 1500 = 0.72 hours (43 minutes).

These are ideal numbers. For lead-acid, halve them to protect the battery.

Frequently Asked Questions

How long will a 12V 100Ah battery run a 1000W inverter?

With a 1000W load and a 12V 100Ah battery, you have 1200 Wh. At 90% efficiency, that’s 1080 Wh. Run time = 1080/1000 = 1.08 hours (about 1 hour 5 minutes). But if the inverter is only 85% efficient, it drops to 0.98 hours. For lead-acid, you should only use half the capacity, so about 30 minutes.

Can I use a car battery with an inverter?

Yes, but only for short periods while the engine is running. Car batteries are not designed for deep discharge. Using them for long run times will damage them. Use a deep-cycle battery (marine or RV) for inverter use.

What size inverter do I need for a refrigerator?

Refrigerators typically draw 100–200W running, but the compressor can surge to 600–1200W for a few seconds. Choose an inverter rated at least 1000W to handle the surge. Check the fridge’s label for the locked rotor amps or starting watts.

How do I convert amp-hours to watt-hours?

Multiply amp-hours by battery voltage. For a 12V battery, 100 Ah × 12V = 1200 Wh. For a 24V battery, 100 Ah × 24V = 2400 Wh. This is the total energy stored, but you can only use a portion depending on battery type.

Does inverter efficiency change with load?

Yes. Most inverters are most efficient at 50–80% of rated load. At 10% load, efficiency can drop to 70–80%. The calculator uses a fixed efficiency, so for very light loads, actual run time will be shorter than estimated.

Can I run an inverter off a solar panel directly?

No. Inverters need a stable DC voltage, which solar panels don’t provide. You need a charge controller and a battery bank. The inverter draws from the battery, and the solar panels recharge the battery.

Related

Formula used
in ah | Battery Capacity | Ah | 100 | 1 | 10000
in v | Battery Voltage | V | 12 | 1 | 600
in eff | Inverter Efficiency | % | 90 | 1 | 99
in w | Load Power | W | 300 | 1 | 50000
out h | Run Time | h | (ah * v * eff/100) / w | 2
out wh | Energy Available | Wh | ah * v * eff/100 | 1

Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work

Method: the standard formula for this calculation, rounded as each result states. See how the calculators work or report an error.